43
Daman Products Company, Inc. •
1811 North Home Street • Mishawaka, IN 46545-7267
Tel: 800.959.7841 574.259.7841 •
Fax: 800.241.7664 • Email: sales@daman.com • www.daman.com
Common cavity:
With solenoid clearance.
C-16-2 (P in nose)
Omit if relief not required
Sun Cavity:
T-16A (P in nose)
See Tech Info for valves.
S
C
Relief cavity is located
left of the isolation.
Relief cavity is located
right of the isolation.
Two relief cavities, one
each side of isolation.
L
R
D
Specify when using a combi-
nation of cavity and isolation
options. Cavities do have
solenoid clearance.
Available with
spacing code 4
PA...PG
Omit if P isolation not required
Available with
spacing code 4
TA...TG
Omit if T isolation not required
X port ISO 4401-07-06
NFPA T3.5.1-D07
Omit if X ports not required
1
P
P
T
Options - D07 High Flow Parallel Manifold
B
A
B
A
B
A
Y
Y
GA
TP
T
P
3.25
[82.5]
4.19
[106.4]
4.00 [101.6] TYP
[120.7]
4.75
[158.8]
6.25
X
X
A
X
B
X port option code 1, (1) per station
Valve cavity location when
Valve cavity location
for cavity-isolation
cavity, or cavity-isolation
combination L or D is specied.
"A" (See chart previous page)
combination R or D.
ISOLATIONS
Daman isolation options allow a manifold
to have two independent pressure and/or
tank ports. Isolations are drilled rather
than plugged to ensure a leakproof and
failproof isolation.
Ordering
code letter:
A
B
C
D
E
F
G
01 & 02
02 & 03
03 & 04
04 & 05
05 & 06
06 & 07
07 & 08
02-08
03-08
04-08
05-08
06-08
07-08
08
* Isolation is
between stations:
Available #
of stations:
Pressure Isolation
Tank Isolation
Pilot Ports
* Stations are numbered left to right.
Contact Daman for cavity locations if
critical.
NOTES:
1) The GA port is not available
on a (1) station manifold.
2) The GA port is not available
when a pressure isolation is
located between stations 1 & 2.
3) Some cavity and isolation
combinations are not possible.
Consult factory to determine
availablity.
Parallel circuit with X
Ordering Information
... /
Pilot Ports Cavity
Pressure
Isolation
Tank Isolation
Cavity &
Isolation
Combinations
P
ABBA
P
T
GA AB
P
T
AB
BA
P
T
AB
P
T
AB
BA
P
T
AB
Parallel Circuit with Isolations
Cavity & Isolation CombinationsParallel Circuit with Cavity
Valves with P in the nose and T out the
side must be used.
Manifold shown with P isolation between 1
& 2 (PA), and T isolation between 2 & 3 (TB).
Option code L
Cavity left of isolation
Option code R
Cavity right of isolation
Option code D includes both cavities
Cavity & Isolation
Combinations
Cavity
Standard
Manifolds
Custom
Products
Cover
Plates
Valve
Adaptors
SubplatesServo Valve
Subplates
Tapping
Plates
Cartridge Valve
Cavity Bodies
Header and
Junction Blocks
Technical
Information